T180 with Koax AP motor drive
01/07/2019

The proven, quiet and patented Koax AP motor drive from Baumeister & Schack will now also move the T180 lifting column series.
Baumeister & Schack has decided to implement this technical change in favor of their modular system. Moreover, this conversion provides a considerably improved flexibility. With this change, a switch is made to a Molex connector, which together with the controlbox provides a better performance and current transmission.
The previous version can still be ordered from stock. From the end of this year, the switch will be made to the new, improved version of the T180 series.
Lifting column T180/3 mini
the smallest version, the T180/3 mini is being replaced by a new comparable performance version:
Article number | Previous: T180K370320DDD24 | New: T180K370320ADD24 |
Voltage | 24 VDC | 24 VDC |
Max. power consumption | 6 A | 6 A |
Force | 800 N | 800 N |
Speed | 30 mm/s | 25 mm/s |
Stroke | 370 mm | 370 mm |
Plug | MAS DIN rond | Molex |
Pulse travel length | 0.7659 mm/ signal | 0.3137 mm/ signal |
Lifting column T180/3
the version with the longest stroke T180/3 is replaced by a new comparable performance version:
Article number | Previous: T180K700580DDD24 | New: T180K700580ADD24 |
Voltage | 24 VDC | 24 VDC |
Max. power consumption | 6 A | 6 A |
Force | 800 N | 800 N |
Speed | 30 mm/s | 25 mm/s |
Stroke | 700 mm | 700 mm |
Plug | MAS DIN round | Molex |
Pulse travel length | 0.7659 mm/ signal | 0.3137 mm/ signal |
Lifting column T180/3 S
the stronger 3-part version can be replaced by the standard T180/3 with less power or by a Visolift lifting column.
Lifting column T180/2
the 2-part version can be replaced by two different types depending on the requirement.
With reduced force 1000 N by the type T180/2 AP or by the Hexalift with 2000 N:
Article number | Previous: T180N500640DDD24 | New: T180I500640ADD24 | New: HM240D500680OFF24 |
Voltage | 24 VDC | 24 VDC | 24 VDC |
Power consumption | 6 A | 6 A | 6 A |
Force | 1500 N | 1000 N | 2000 N |
Speed | 15 mm/s | 25 mm/s | 9 mm/s |
Stroke | 500 mm | 500 mm | 500 mm |
Retracted length | 640 mm | 640 mm | 680 mm |
Plug | MAS DIN round | Molex | Molex |
Pulse travel length | 0.7659 mm/ signal | 0.3137 mm/ signal | 0.0941 mm/ signal |
Bear in mind that synchronous operation of the old and new types is not possible because different transmission ratios and therefore different pulse numbers per mm are available. Also, the parameter set on the controller from the previous to the new version does not match. This is why we always ask you to remove or upgrade the old column for a set.