C2-20

C2-20 Advanced Actuator Controller

The C2-20 actuator controller provides advanced positioning and control of actuators through
easy and flexible integration with the application. The controller is designed to work with Concens electrical in-line actuators in applications where positioning is required. C2-20 has adjustable start and stop ramps, which make smooth starts and stops possible. The C2-20 works in conjunction with actuators with hall only.

Adjustable current limits in both directions protect the motor against overcurrent. In learning mode the number of hall pulses in a full stroke of the actuator is counted which enables accurate positioning during normal operation.

The position of the actuator is controlled by a DC voltage between 0-5,4 or 0-10,8 volts to
the C2-20. Adjustments and parameter settings like current limit value, ramp times, speed etc. are set with C2-PROG interface unit or C2-USB “dongle” connected to a PC.

Properties

  • Precise stroke control from analog voltage input
  • Full H-bridge DC motor controller
  • Programmable using the C2-PROG interface unit or a PC with a USB cable and dongle
  • Fast change of direction
  • Soft start-up, acceleration ramp
  • Settable current limit
  • Trip or continuous current limit
  • High efficiency
  • High momentary load capacity
  • Rail base fittable
  • Two control modes
  • 15 parameters can be controlled by USB interface
  • 'Position Reached'-signal

Warnings and recommendations

  • Attention! C2-20 has no fuse in it. Use external fuse according to application.
    If C2-20 goes into “trip” (overcurrent) it is only possible to run actuator in opposite direction.
  • Please adjust the max. current to be 10% higher than maximum current during load. This ensures the longest actuator lifetime.
  • Please ensure that the power supply for the controller is capable of supplying sufficient current – otherwise the controller and the actuator may be damaged.
  • Double-check correct polarity of power supply. If connected wrong the C2-20 will be damaged.
  • If wire colors differ from what is expected, please check with supplier or check on our YouTube channel before connecting the actuator to the controller.
  • Connect to power during programming.
  • Concens does not have any responsibility over the possible errors in this data sheet. Specifications are to be changed without notice.

Alternatives

C2-10

  • Current limit
  • I-Trip function
  • Two control modes
  • Plug&Play
Delivery time: 5 workdays
Op voorraad
© A&E Trading b.v. 2019
Made by Convident